IS AN ELEMENT FOR CV52035 CVM200 Series. Maximum blow-by flow rate = 200 lpm/7.1 cfm. Blow-by outlet port in 9 o'clock position. 4-bolt integral mounting bracket
IS AN ELEMENT FOR CV52036 CVM200 Series. Maximum blow-by flow rate = 200 lpm/7.1 cfm. Blow-by outlet port in 3 o'clock position. 4-bolt integral mounting bracket
IS AN ELEMENT FOR CV52008 Model CVM280B. Maximum blow-by flow rate = 280 L/Min 4 Bolt Integral Mounting Interface with By-pass valve. Delta P at Rated Flow 1.25
IS AN ELEMENT FOR CV52015 Model CVM280B. Maximum blow-by flow rate = 280 L/Min 4 Bolt Integral Mounting Interface with By-pass valve. Delta P at Rated Flow 1.25
IS AN ELEMENT FOR CV52017 Model CVM424T. Maximum blow-by flow rate = 424L/Min 4 Bolt Integral Mounting Interface with By-pass valve. Delta P at Rated Flow 1.25
IS AN ELEMENT FOR CV52019 Model CVM280T. Maximum blow-by flow rate = 280 L/Min 4 Bolt Integral Mounting Interface with By-pass valve. Delta P at Rated Flow 1.25
IS AN ELEMENT FOR CV52021 Model CVM280T. Maximum blow-by flow rate = 280 L/Min 4 Bolt Integral Mounting Interface with By-pass valve. Delta P at Rated Flow 1.25
IS AN ELEMENT FOR CV52034 Model CVM280B. Maximum blow-by flow rate = 280 L/Min 4 Bolt Integral Mounting Interface with By-pass valve. Delta P at Rated Flow 1.25
IS AN ELEMENT FOR CV52006 Model CVM424B. Maximum blow-by flow rate = 424 L/Min 4 Bolt Integral Mounting Interface with By-pass valve. Delta P at Rated Flow 1.25
IS AN ELEMENT FOR CV52007 Model CVM424T. Maximum blow-by flow rate = 424L/Min 4 Bolt Integral Mounting Interface with By-pass valve. Delta P at Rated Flow 1.25
IS AN ELEMENT FOR CV52009 Model CVM424B. Maximum blow-by flow rate = 424 L/Min 4 Bolt Integral Mounting Interface with By-pass valve. Delta P at Rated Flow 1.25
IS AN ELEMENT FOR CV52016 Model CVM424B. Maximum blow-by flow rate = 424 L/Min 4 Bolt Integral Mounting Interface with By-pass valve. Delta P at Rated Flow 1.25
IS AN ELEMENT FOR CV52017 Model CVM424T. Maximum blow-by flow rate = 424L/Min 4 Bolt Integral Mounting Interface with By-pass valve. Delta P at Rated Flow 1.25
IS AN ELEMENT FOR CV52028 Model CVM424T. Maximum blow-by flow rate = 424L/Min 4 Bolt Integral Mounting Interface with By-pass valve. Delta P at Rated Flow 1.25
USES ELEMENT CV52055 Crankcase Coalescer Element. For use with CVM200 Series
USES SERVICE PART Q458222A One-way check valve. Inlet & Outlet Hose Barb Diameter 10.75mm (0.423 in.). Valve to be installed in a vertical orientation. Valve ope
USES ELEMENT CV52055 Crankcase Coalescer Element. For use with CVM200 Series
USES SERVICE PART Q458222A One-way check valve. Inlet & Outlet Hose Barb Diameter 10.75mm (0.423 in.). Valve to be installed in a vertical orientation. Valve ope
USES ELEMENT CV52052 Coalescer element CVM424 Units
USES SERVICE PART Q458222A One-way check valve. Inlet & Outlet Hose Barb Diameter 10.75mm (0.423 in.). Valve to be installed in a vertical orientation. Valve ope
USES ELEMENT CV52052 Coalescer element CVM424 Units
USES SERVICE PART Q458222A One-way check valve. Inlet & Outlet Hose Barb Diameter 10.75mm (0.423 in.). Valve to be installed in a vertical orientation. Valve ope